DBX1000M-6" Installation Instructions
- Orient box to match desired venting direction. Allow a minimum of 4” of vent pipe to extend into the box.
- If gas line is to be installed, insert into knockout provided.
- Slide box into position taking care to correctly align vent pipe and gas pipe (if present).
- Set box so that the bottom is 2 5/8” above the floor to allow clearance for the trim ring.
- Attach box directly to either framing member and use straps to secure the other side to the opposite framing member.
- Screws or nails (1 ¼”) in length to attach the DBX1000M Box to framing.
- Trim carpenter to leave 1 ½” between inside edge of box and end of baseboard to allow trim ring clearance.
- Snap trim ring into opening, No Caulking Required.
- Trim Ring is powder coated, no finishing required.
- Trim Ring accommodates ½” or 5/8” drywall.