{"title":"InOvate DryerJack® Dryer Roof Vents","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eInOvate DryerJack® Dryer Roof Vents\u003c\/strong\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eShop genuine \u003cstrong\u003eInOvate DryerJack® dryer roof vents\u003c\/strong\u003e engineered specifically for terminating dryer exhaust through the roof. Unlike conventional roof caps, DryerJack models are designed to provide efficient airflow while helping reduce lint buildup and airflow restriction.\u003c\/p\u003e\n\u003cp\u003eSolid Source HVAC carries DryerJack roof vent options for different roof configurations and clearance requirements, including the \u003cstrong\u003eDryerJack 486 Extra-Clearance Dryer Roof Vent\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt Specifically for Dryer Exhaust\u003c\/strong\u003e\u003cbr\u003eDryerJack roof vents provide a durable, professional termination for residential, multifamily and commercial dryer exhaust systems.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/solidsourcehvac.com\/pages\/contact-us-large-quantity-discounts\"\u003e\u003cstrong\u003eBuying for a multifamily or commercial project?\u003c\/strong\u003e\u003c\/a\u003e Ask about contractor and job-quantity pricing for larger DryerJack orders.\u003c\/p\u003e","products":[{"product_id":"inovate-dryerjack-low-profile-roof-vent-with-roof-neck","title":"InOvate DryerJack 4\" Low-Profile Dryer Roof Vent","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003e\u003cstrong\u003eStop Lint Buildup and Airflow Restrictions at the Roof\u003c\/strong\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe InOvate DryerJack 477 is a low-profile roof termination engineered specifically for 4-inch dryer exhaust systems. Its curved damper, large exhaust opening, and low-profile hood are designed to minimize airflow restriction while providing a durable, weather-resistant roof termination.\u003c\/p\u003e\n\u003cp\u003eVenting a dryer through the roof can help shorten the total duct run in certain installations. The DryerJack provides a purpose-built alternative to conventional roof vents that may restrict airflow or use screens that are not permitted for dryer exhaust applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeed Additional Roof Clearance?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShop the \u003ca href=\"https:\/\/solidsourcehvac.com\/products\/dryerjack-model-486-extra-clearance-roof-dryer-vent-4-galvalume-roof-termination-with-pest-guard-clean-out-door-manufactured-in-the-usa\"\u003eDryerJack 486 Extra-Clearance Roof Vent →\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eBest Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDryer exhaust through the roof\u003c\/li\u003e\n\u003cli\u003eAsphalt-shingle roofs\u003c\/li\u003e\n\u003cli\u003eMetal roofs\u003c\/li\u003e\n\u003cli\u003eLow-profile tile roofs\u003c\/li\u003e\n\u003cli\u003eRoof pitches from 3\/12 to 12\/12\u003c\/li\u003e\n\u003cli\u003eNew construction and retrofit applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose the DryerJack 477?\u003c\/h3\u003e\n\u003cp\u003e✓ \u003cstrong\u003eDesigned Specifically for Dryer Exhaust\u003c\/strong\u003e — Purpose-built as a non-restrictive dryer roof termination.\u003c\/p\u003e\n\u003cp\u003e✓ \u003cstrong\u003eMaximum Airflow Efficiency\u003c\/strong\u003e — The curved damper, hood dimensions, and collar placement work together to minimize airflow restriction.\u003c\/p\u003e\n\u003cp\u003e✓ \u003cstrong\u003eLow-Profile Design\u003c\/strong\u003e — At less than 5 inches tall, the 477 provides a cleaner, less obtrusive roof appearance.\u003c\/p\u003e\n\u003cp\u003e✓ \u003cstrong\u003eEasy Cleaning Access\u003c\/strong\u003e — The hood design accommodates cleaning tools for easier dryer-duct maintenance.\u003c\/p\u003e\n\u003cp\u003e✓ \u003cstrong\u003eBird \u0026amp; Rodent Deterrence\u003c\/strong\u003e — The damper closure is designed to help deter birds and rodents without using an airflow-restricting screen.\u003c\/p\u003e\n\u003cp\u003e✓ \u003cstrong\u003eHeavy-Gauge Metal Construction\u003c\/strong\u003e — Built in the USA from durable Galvalume® steel for long-term exterior use.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e DJK477\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuct connection:\u003c\/strong\u003e 4-inch dryer exhaust\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Galvalume® steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase \u0026amp; hood:\u003c\/strong\u003e 22-gauge Galvalume®\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDamper:\u003c\/strong\u003e 26-gauge Galvalume®\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof pitch:\u003c\/strong\u003e 3\/12–12\/12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAvailable finishes:\u003c\/strong\u003e Black, Brown and Mill Finish\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Dryer exhaust roof termination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Suitable for new construction and retrofit installations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMade in:\u003c\/strong\u003e USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCode Compliance\u003c\/h3\u003e\n\u003cp\u003eAccording to InOvate's current DryerJack technical documentation, the DryerJack 477 complies with \u003cstrong\u003eIMC 504.4 and IRC 1502.3\u003c\/strong\u003e requirements applicable to dryer exhaust terminations. Always verify applicable local code requirements and installation requirements for your project.\u003c\/p\u003e\n\u003ch3\u003eDryer Venting Through the Roof\u003c\/h3\u003e\n\u003cp\u003eA properly designed roof termination is particularly important for dryer exhaust because excessive restriction can reduce airflow and contribute to lint accumulation. The DryerJack is engineered specifically for this application, using a curved damper and unrestricted opening rather than a screen at the termination.\u003c\/p\u003e\n\u003cp\u003eFor installation dimensions and requirements, refer to the manufacturer's installation and specification documents.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DryerJack 477 be used for dryer exhaust?\u003c\/strong\u003e\u003cbr\u003eYes. The DryerJack 477 is specifically engineered as a 4-inch dryer exhaust roof termination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat roof types can I install it on?\u003c\/strong\u003e\u003cbr\u003eInOvate lists the 477 for asphalt shingles, metal roofing, and low-profile tile roofs with pitches between 3\/12 and 12\/12.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the DryerJack have a screen?\u003c\/strong\u003e\u003cbr\u003eNo. The DryerJack uses a damper rather than a screen at the dryer exhaust termination.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's the difference between the 477 and 486?\u003c\/strong\u003e\u003cbr\u003eThe 477 is the low-profile model. The DryerJack 486 provides additional clearance for applications such as higher-profile tile and heavier-snow conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the DryerJack be cleaned?\u003c\/strong\u003e\u003cbr\u003eYes. The 477 hood is designed to accommodate cleaning tools for dryer-vent maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you offer contractor and project pricing?\u003c\/strong\u003e\u003cbr\u003eYes. Solid Source HVAC offers quantity pricing for contractors, multifamily projects, and larger orders. Use the Contractor \u0026amp; Bulk Pricing link above to request pricing.\u003c\/p\u003e\n\u003cp\u003eThe technical claims above are based on InOvate's current DryerJack materials.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan class=\"a-list-item\" style=\"color: #000000;\"\u003e\u003ca href=\"https:\/\/solidsourcehvac.com\/pages\/dryerjack-477-installation\"\u003eClick here\u003c\/a\u003e for more specs and installation specifics.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"a-list-item\"\u003e\u003ciframe title=\"DryerJack DJK477 Installation\" src=\"https:\/\/www.youtube.com\/embed\/ZbxopQkzEXc\" height=\"385\" width=\"684\"\u003e\u003c\/iframe\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Inovate","offers":[{"title":"Black","offer_id":42544091168940,"sku":"DryerJack-Black","price":53.9,"currency_code":"USD","in_stock":true},{"title":"Brown","offer_id":42544091201708,"sku":"DryerJack-Brown","price":53.9,"currency_code":"USD","in_stock":true},{"title":"Mill Finish","offer_id":42544091234476,"sku":"","price":53.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1730\/3739\/files\/Black1.jpg?v=1682766976"},{"product_id":"dryerjack-model-486-extra-clearance-roof-dryer-vent-4-galvalume-roof-termination-with-pest-guard-clean-out-door-manufactured-in-the-usa","title":"InOvate DryerJack 486 4\" Extra-Clearance Dryer Roof Vent","description":"\u003ch3 class=\"PDq2pG_selectionAnchorContainer\"\u003eExtra-Clearance Dryer Roof Vent for High-Airflow Dryer Exhaust\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eInOvate DryerJack 486\u003c\/strong\u003e is a heavy-duty 4-inch dryer roof vent designed specifically for clothes dryer exhaust systems. Its extra-clearance design provides increased airflow space beneath the hood while helping reduce lint buildup and airflow restriction.\u003c\/p\u003e\n\u003cp\u003eEngineered for efficient dryer exhaust termination through the roof, the \u003cstrong\u003eDryerJack 486\u003c\/strong\u003e features a large opening, smooth airflow path and gravity-operated damper that opens easily during dryer operation and closes when the dryer is off.\u003c\/p\u003e\n\u003cp\u003eBuilt from durable galvanized steel, the \u003cstrong\u003eDryerJack 486\u003c\/strong\u003e is \u003cstrong\u003edesigned for residential, multifamily and commercial dryer exhaust applications\u003c\/strong\u003e where reliable airflow and long-term performance are important.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDon't need the extra clearance?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eShop the \u003ca href=\"https:\/\/solidsourcehvac.com\/products\/inovate-dryerjack-low-profile-roof-vent-with-roof-neck\"\u003eDryerJack 477 Low-Profile Dryer Roof Vent →\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eBest Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDryer exhaust through the roof\u003c\/li\u003e\n\u003cli\u003eHigher-profile tile roofs\u003c\/li\u003e\n\u003cli\u003eApplications requiring additional roof clearance\u003c\/li\u003e\n\u003cli\u003eSnowfall-prone installations\u003c\/li\u003e\n\u003cli\u003eResidential construction\u003c\/li\u003e\n\u003cli\u003eMultifamily construction\u003c\/li\u003e\n\u003cli\u003eNew construction and retrofit applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy Choose the DryerJack 486?\u003c\/h3\u003e\n\u003cp\u003e✓ \u003cstrong\u003eExtra-Clearance Design\u003c\/strong\u003e — The taller profile provides additional clearance compared with the low-profile DryerJack 477.\u003c\/p\u003e\n\u003cp\u003e✓ \u003cstrong\u003eDesigned for Dryer Exhaust\u003c\/strong\u003e — Purpose-built as a non-restrictive dryer roof termination.\u003c\/p\u003e\n\u003cp\u003e✓ \u003cstrong\u003eEfficient Airflow\u003c\/strong\u003e — The curved damper and interior design help minimize airflow restriction.\u003c\/p\u003e\n\u003cp\u003e✓ \u003cstrong\u003eEasy Cleaning Access\u003c\/strong\u003e — A removable access panel provides convenient access for dryer-duct inspection and cleaning.\u003c\/p\u003e\n\u003cp\u003e✓ \u003cstrong\u003eBird \u0026amp; Rodent Deterrence\u003c\/strong\u003e — The damper design helps deter bird and rodent entry without an airflow-restricting screen.\u003c\/p\u003e\n\u003cp\u003e✓ \u003cstrong\u003eHeavy-Duty Construction\u003c\/strong\u003e — Manufactured from rugged 26-gauge Galvalume® steel.\u003c\/p\u003e\n\u003cp\u003e✓ \u003cstrong\u003eMade in the USA\u003c\/strong\u003e — Manufactured by InOvate Technologies.\u003c\/p\u003e\n\u003ch3\u003e477 vs. 486: Which DryerJack Do I Need?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eChoose the \u003ca href=\"https:\/\/solidsourcehvac.com\/products\/inovate-dryerjack-low-profile-roof-vent-with-roof-neck\"\u003eDryerJack 477\u003c\/a\u003e\u003c\/strong\u003e when you want a low-profile dryer roof termination for standard metal, low-profile tile or asphalt-shingle roof applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose the DryerJack 486 \u003c\/strong\u003ewhen the installation requires \u003cstrong\u003eadditional clearance\u003c\/strong\u003e, particularly with higher-profile tile or snowfall conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e DJK486\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDuct connection:\u003c\/strong\u003e 4-inch dryer exhaust\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e 26-gauge Galvalume® steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall base:\u003c\/strong\u003e 12\" × 14\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall height:\u003c\/strong\u003e approximately 9\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCollar:\u003c\/strong\u003e 1.25\" above and 3\" below plate\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess:\u003c\/strong\u003e Removable access panel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Extra-clearance dryer roof termination\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConstruction:\u003c\/strong\u003e Suitable for new and retrofit applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMade in:\u003c\/strong\u003e USA \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCode Compliance\u003c\/h3\u003e\n\u003cp\u003eAccording to InOvate's technical documentation, the DryerJack 486 is designed as a non-restrictive dryer roof vent termination and complies with \u003cstrong\u003eIMC 504.4 and IRC 1502.3\u003c\/strong\u003e. Always verify applicable local codes and installation requirements for your project. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between the DryerJack 477 and 486?\u003c\/strong\u003e\u003cbr\u003eThe 477 is InOvate's low-profile model. The 486 has a taller, extra-clearance design intended for applications such as higher-profile tile and snowfall conditions. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the DryerJack 486 designed for dryer exhaust?\u003c\/strong\u003e\u003cbr\u003eYes. InOvate specifically engineers DryerJack roof terminations for dryer exhaust applications. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the 486 have a clean-out access panel?\u003c\/strong\u003e\u003cbr\u003eYes. The 486 includes a removable access panel to make duct cleaning and maintenance easier. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it use a screen to keep animals out?\u003c\/strong\u003e\u003cbr\u003eNo. Dryer exhaust terminations should not rely on a screen. The DryerJack uses a damper design that InOvate says helps deter bird and rodent entry. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the DryerJack 486 made in the USA?\u003c\/strong\u003e\u003cbr\u003eYes. InOvate identifies DryerJack products as made in the USA.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1730\/3739\/files\/DJK486-Specs.png?v=1769544181\" alt=\"\"\u003e\u003c\/p\u003e","brand":"Inovate","offers":[{"title":"Black","offer_id":45284078256300,"sku":"DJK486K","price":69.25,"currency_code":"USD","in_stock":false},{"title":"Brown","offer_id":45284078223532,"sku":"DJK486B","price":69.25,"currency_code":"USD","in_stock":false},{"title":"Mill Finish","offer_id":45284078190764,"sku":"DJK486-Mill","price":69.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1730\/3739\/files\/black_7541b835-0c51-4b33-977f-103fd3e3afcc.jpg?v=1769544836"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1730\/3739\/collections\/logo_4ec6b568-2713-4100-990b-3c20eb85a0a5.png?v=1786722065","url":"https:\/\/solidsourcehvac.com\/collections\/inovate-dryerjack-dryer-roof-vents.oembed","provider":"Solid Source HVAC","version":"1.0","type":"link"}